Field Description
real time data is routed.
Queues/Policies Configure the desired QoS queues.
For each class created from the class plan, which is associated
with the selected interface, a queue is generated automatically
and displayed here (only for outgoing classified data traffic and
for data traffic classified in both directions).
Add a new entry with Add. The Edit Queues/Policies menu
opens.
The Edit Queues/Policies menu consists of the following fields:
Fields in the Edit Queues/Policies menu
Field Description
Description Enter the name of the queue/policy.
Outgoing Interface
Shows the interface for which the QoS Queues are being con-
figured.
Priorisation queue Select the queue priority type.
Possible values:
+2 (  (default value): Queue for data classified as
“normal”.
=$1 "-: Queue for data classified as “high priority”.
92": Queue for data that has not been classified or data
of a class for which no specific queue has been configured.
Class ID Only if Priority Queue = +2 # .
Select the QoS packet class to which this queue is to apply.
To do this, at least one class ID must be given in the Routing -
> QoS -> QoS Classification menu.
Priority Only if Priority Queue = +2 # .
Choose the priority of the queue. Possible values are to &.
The default value is .